How the hydro process works:
http://www.youtube.com/watch?v=4JJUt6s- ... r_embedded

Why you should NEVER put oil on the reg-to-bottle side.
http://www.pbnation.com/showthread.php? ... st72124072

The thread says to get your tank hydro'd, but that's really only necessary if you're:

a. transporting the tank to meet legal requirements
b. playing at an official place that requires it

If you actually think about it, a hydro is the roughest thing you can do to a tank. They fill it up to around 7000psi under water. Carbon fibre doesn't have the same stress curve as something like steel (ie. it contracts/deforms depending on the load). I'd be more worried about a hairline crack developing rather than DOT rules, but to each their own.

Either way, never use oil! Grease is acceptable; loc-tite will usually make it fail hydro (they worry about it plugging the release valve).
Attachments
oil2g.jpg
(18.24 KiB) Downloaded 4 times
oil3.jpg
(12.31 KiB) Downloaded 4 times
oilp.jpg
(15.28 KiB) Downloaded 4 times
oil5.jpg
(12.83 KiB) Downloaded 4 times
oil4.jpg
(17.79 KiB) Downloaded 4 times
757_46bc13692edda.jpg
(19.63 KiB) Downloaded 4 times
757_46bc1315f01fc.jpg
(18.34 KiB) Downloaded 3 times
DSC00135.jpg
DSC00134.jpg
DSC00133.jpg
blown-up-bottle.jpg
blownbottles005.jpg
******* /=========\Image
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|
Image
¨˜”°º•[K]•º°”˜¨
User avatar
[PX]IronFist
Posts: 3165
Joined: Sun Mar 23, 2003 10:28 pm
Location: Mossley. Ontario
Contact:

Re: Hydro

Post by [PX]IronFist »

Just to be clear the No-Oil rule applies only to HPA tanks.
Ilon "Rezzer" Rezon in the Late Era RPG
User avatar
THE JEW (RaVeN)
Posts: 12499
Joined: Sun Mar 23, 2003 2:52 pm
Location: Bethlehem ;)
Contact:

Re: Hydro

Post by THE JEW (RaVeN) »

I wouldn't use oil when changing a CO2 pin-valve either. O-ring lubricant and a very small amount of thread-locker would be my choice. Why use oil when there's so many alternatives? I'll admit it'd likely only be a problem if a burst disc went and it vented a large amount of oil at 1500psi. But I wouldn't risk what I don't have to. *shrug*
******* /=========\Image
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|
Image
¨˜”°º•[K]•º°”˜¨
User avatar
THE JEW (RaVeN)
Posts: 12499
Joined: Sun Mar 23, 2003 2:52 pm
Location: Bethlehem ;)
Contact:

Re: Hydro

Post by THE JEW (RaVeN) »

Dear Ben,

We have received your inquiry about the Hazardous Materials Regulations
(HMR; 49 CFR Parts 171-180). The HMR are available at the following URL:

http://hazmat.dot.gov/rules.htm

Periodic requalification of DOT specification cylinders is specified in §
180.209. Any cylinder not exceeding 2 inches in outside diameter is not
subject to the volumetric expansion test.

If you require further assistance, our Hazardous Materials Information
Center is staffed with regulatory specialists who can quickly answer your
questions by phone. Please do not hesitate to call, as the Information
Center is open Monday through Friday, 9 am - 5 pm E.S.T. at (800) 467-4922
or (202) 366-4488.

Sincerely,

Kurt Eichenlaub, Hazardous Materials Specialist


http://www.network54.com/Forum/9013/mes ... om+the+DOT
******* /=========\Image
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|
Image
¨˜”°º•[K]•º°”˜¨
User avatar
THE JEW (RaVeN)
Posts: 12499
Joined: Sun Mar 23, 2003 2:52 pm
Location: Bethlehem ;)
Contact:

Re: Hydro

Post by THE JEW (RaVeN) »

On steel tanks the markings are on the crown (just below the neck).

The Department of Transportation (DOT) and Transport Canada (TC) require that cylinders made in compliance to their specifications be marked on the crown with certain information. Over the years the format used by Catalina Cylinders and Cliff Impact Division of Catalina Cylinders to display these markings has changed a few times. Shown below is an example of the current crown marking stamped on the standard 20 # CO2 cylinders manufactured at Catalina Cylinders, Garden Grove, CA. Under the example of the crown marking is a list of each of the specific crown markings, followed by a brief explanation of that marking. The descriptions of the markings are the same regardless of the different stamping formats used over the years .

Example of crown markings on a 20 # CO2 Cylinder:

DOT-3AL1800FXXXXXXX M4002 07C08 B20 U18 T25.2LB TC-3ALM124 T11.5KG CATALINA

Marking Description
DOT-3AL The U.S. regulatory authority, the Department of Transportation (DOT), and specification, 3AL, to which the cylinder is manufactured in compliance(required mark).

1800 The service pressure, in pounds per square inch (psi), of the cylinder (required mark).

FXXXXXXX The serial number of the cylinder. For Catalina Cylinders, the serial number prefix of "F" is specific to the 20# CO2 cylinders followed by a seven digit number.

M4002 The M-number or Manufacturers Number issued by the DOT to the manufacturer, Catalina Cylinders.

07C08 The original hydrostatic test date of the cylinder, month followed by year, performed at the time of manufacture of the cylinder. The C represents the symbol of the Independent Inspection Agency (IIA) performing the inspection of and certifying the acceptance of the cylinder at the time of manufacture (required mark).

B20 The cylinder identifier (product name). It identifies the market, "B" for beverage, and capacity "20" for a capacity of 20# of CO2 charge, of the cylinder.

U18 The cylinder outlet thread designation as specified in CGA TB-16.

T25.2LB or TW25.0LBS The tare weight (in lbs.) of the empty cylinder package. The empty cylinder package includes the cylinder, the valve, the carrying handle and the snap ring (required mark).

TC-3ALM The Canadian regulatory authority, Transport Canada (TC), and specification, 3ALM, to which the cylinder is manufactured in compliance (required mark).

124 The service pressure of the cylinder expressed in metric units, bars (required mark).

CATALINA The name of the manufacturer of the cylinder.

T11.5KG The metric tare weight (in kgs) of the empty cylinder package. The empty cylinder package includes the cylinder, the valve, the carrying handle and the snap ring.
Attachments
hpalabel.jpg
******* /=========\Image
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|
Image
¨˜”°º•[K]•º°”˜¨
Post Reply

Return to “Paintball Fourm”