Phase Change
Moderators: THE JEW (RaVeN), Ghost [PX]
- THE JEW (RaVeN)
- Posts: 12499
- Joined: Sun Mar 23, 2003 2:52 pm
- Location: Bethlehem ;)
- Contact:
Phase Change
OCZ is going to bring out its own phase change unit:
http://www.hexus.net/content/item.php?item=4272
From the sounds of it, this unit will be cheaper than those from Vapochill and Prometia.
http://www.hexus.net/content/item.php?item=4272
From the sounds of it, this unit will be cheaper than those from Vapochill and Prometia.
******* /=========\
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|

¨˜”°º•[K]•º°”˜¨
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|

¨˜”°º•[K]•º°”˜¨
- THE JEW (RaVeN)
- Posts: 12499
- Joined: Sun Mar 23, 2003 2:52 pm
- Location: Bethlehem ;)
- Contact:
WOW! When I said cheap, I had no idea how cheap!
http://anandtech.com/tradeshows/showdoc.aspx?i=2669&p=2
The phase kit will be between $200 and $300 U.S. which means it will cost as much as a high end watercooling kit. Amazing value. I imagine it'll only be single phase, but still...........that's FAR less than the typical $1000 you'd pay for a Vapo/Prommie.
http://anandtech.com/tradeshows/showdoc.aspx?i=2669&p=2
The phase kit will be between $200 and $300 U.S. which means it will cost as much as a high end watercooling kit. Amazing value. I imagine it'll only be single phase, but still...........that's FAR less than the typical $1000 you'd pay for a Vapo/Prommie.
******* /=========\
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|

¨˜”°º•[K]•º°”˜¨
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|

¨˜”°º•[K]•º°”˜¨
- THE JEW (RaVeN)
- Posts: 12499
- Joined: Sun Mar 23, 2003 2:52 pm
- Location: Bethlehem ;)
- Contact:
Refrigeration Basics:
http://www.refrigerationbasics.com/
http://www.refrigerationbasics.com/1024x768/rb1.htm
Excellent Guides (ie. Pressure Vs. Temp, etc.):
http://refrigerants.dupont.com/Suva/en_ ... k10912.pdf
http://www.xtremesystems.org/forums/sho ... p?t=104330
http://www.refrigerationbasics.com/
http://www.refrigerationbasics.com/1024x768/rb1.htm
Excellent Guides (ie. Pressure Vs. Temp, etc.):
http://refrigerants.dupont.com/Suva/en_ ... k10912.pdf
http://www.xtremesystems.org/forums/sho ... p?t=104330
Last edited by THE JEW (RaVeN) on Mon Sep 18, 2006 11:25 am, edited 1 time in total.
******* /=========\
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|

¨˜”°º•[K]•º°”˜¨
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|

¨˜”°º•[K]•º°”˜¨
- THE JEW (RaVeN)
- Posts: 12499
- Joined: Sun Mar 23, 2003 2:52 pm
- Location: Bethlehem ;)
- Contact:
Insulating Guide:
http://www.devilmaster.org/modules.php? ... le&sid=103
http://www.devilmaster.org/modules.php? ... le&sid=103
******* /=========\
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|

¨˜”°º•[K]•º°”˜¨
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|

¨˜”°º•[K]•º°”˜¨
- THE JEW (RaVeN)
- Posts: 12499
- Joined: Sun Mar 23, 2003 2:52 pm
- Location: Bethlehem ;)
- Contact:
Guides:
http://www.phase-change.com/index.php?a ... =23&page=1
http://www.overclockers.com/tips1238/
http://gomeler.com/2006/04/16/vapor-pha ... e-cooling/
http://forums.extremeoverclocking.com/s ... p?t=233054
http://www.overclock3d.net/forums/showthread.php?t=5554
http://overclockers.com/tips1032/
http://www.phase-change.com/index.php?a ... =23&page=1
http://www.overclockers.com/tips1238/
http://gomeler.com/2006/04/16/vapor-pha ... e-cooling/
http://forums.extremeoverclocking.com/s ... p?t=233054
http://www.overclock3d.net/forums/showthread.php?t=5554
http://overclockers.com/tips1032/
******* /=========\
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|

¨˜”°º•[K]•º°”˜¨
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|

¨˜”°º•[K]•º°”˜¨
-
[PX]Kal Bob
- Site Admin
- Posts: 1959
- Joined: Sun Mar 23, 2003 1:41 am
- Location: Stalinist Russia!
- Contact:
THE JEW (RaVeN) wrote:Insulating Guide:
http://www.devilmaster.org/modules.php? ... le&sid=103
Forgive me if i am blind, but this artical appers to be in Spanish.
Jew, was this a test to see if we read any of your posts? lol
KalNet SysAdmin.
Elitism- It's Lonely At The Top. But It's Comforting To Look Down Upon Everyone At The Bottom.
Elitism- It's Lonely At The Top. But It's Comforting To Look Down Upon Everyone At The Bottom.
- THE JEW (RaVeN)
- Posts: 12499
- Joined: Sun Mar 23, 2003 2:52 pm
- Location: Bethlehem ;)
- Contact:
[PX]Kal Bob wrote:THE JEW (RaVeN) wrote:Insulating Guide:
http://www.devilmaster.org/modules.php? ... le&sid=103
Forgive me if i am blind, but this artical appers to be in Spanish.
Jew, was this a test to see if we read any of your posts? lol
Nope, the pictures are universal
******* /=========\
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|

¨˜”°º•[K]•º°”˜¨
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|

¨˜”°º•[K]•º°”˜¨
- THE JEW (RaVeN)
- Posts: 12499
- Joined: Sun Mar 23, 2003 2:52 pm
- Location: Bethlehem ;)
- Contact:
TXV's: http://hvacwebtech.com/marksM2.htm
Charging systems: http://www.refrigtech.com/charge.html
Rules of thumb for heat loads: http://www.ryanairconspares.com/informa ... info_id=17
Many info documents: http://www.hvacrinfo.com/ae_index.htm
Charging systems: http://www.refrigtech.com/charge.html
Rules of thumb for heat loads: http://www.ryanairconspares.com/informa ... info_id=17
Many info documents: http://www.hvacrinfo.com/ae_index.htm
******* /=========\
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|

¨˜”°º•[K]•º°”˜¨
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|

¨˜”°º•[K]•º°”˜¨
- THE JEW (RaVeN)
- Posts: 12499
- Joined: Sun Mar 23, 2003 2:52 pm
- Location: Bethlehem ;)
- Contact:
A decent capacity system:
http://xtremesystems.org/forums/showpos ... stcount=12
http://xtremesystems.org/forums/showpos ... stcount=12
Temp rang is just that, It will move X amount of BTU Inside that range at Y super heat
You are correct as far as lower temp = lower capacity, thats what the valve does, it throttles the refrigerant flow to match evap load to maintain super heat. Its most effective range is inside the window they list 15F to -40F is a common commercial refrigeration range.
You are correct again, a receiver acts as a buffer tank to ensure a solid liquid column to the valve, as the valve throttles back the now un-needed flow is held in the receiver until called upon by the TXV.
You are correct as to the load, The BTU/H is what is needed strictly to hold the 400w load, how ever we all so have to A:pull it down to that, B:We have to fight external heat influx, C: We have the heat of the compressor too we must reject.
Your average system of 6,000BTU will use the 6,000 mostly to pull down the loaded area, then as it throttles to temp in the end it may only be moving 1,000BTU once there to maintain the temp.
As for the valve ranges, it is the max the valve can move wide open at its rated refrigerant at its rated pressure drop during pull down.
Simple calcs or selection in refrigeration? Not really, it just seems simple after a while as you know what to ruffly expect, but you get ruff performance to go along with the guesstimate.
For a good performing chiller with allot of room for expansion I'd say find a nice 3,100BTU @ 45F evap compressor, with a 5,000BTU condenser and a 1/4Ton mid temp TXV, and use a 6,000BTU exchanger, the ones RunMC has are nice and cheap (Good deal for us in Canada! even after shipping!!) for that as an evap you wouldn't need an EQ valve.
That should offer a good performing system with low power consumption with room to expand and should hold you at a nice chilly load.
Best way is get one to play with, they are extremely forgiving about charge and system construction, as you gain experience with how they preform and such you can focuser on streamlining and improving your design.
Check out this: http://hvacwebtech.com/marksM2.htm < TXVs explained.
******* /=========\
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|

¨˜”°º•[K]•º°”˜¨
****(_]/_____________\[_)
***** /(__)==JEW==(__)\
***** |=o__________o=|
***** |_|====---====|_|

¨˜”°º•[K]•º°”˜¨
- THE JEW (RaVeN)
- Posts: 12499
- Joined: Sun Mar 23, 2003 2:52 pm
- Location: Bethlehem ;)
- Contact: